Teradata Database Errors

Teradata error TDP0388 TDPWTO: UNABLE TO SEND REQUIRED OPERATOR MESSAGE

Teradata code TDP0388 TDPWTO: UNABLE TO SEND REQUIRED OPERATOR MESSAGE

Error description

error explanation...

Explanation: TDP encountered an error while requesting an action or security message be sent to to an operator console.

Similar errors for non-critical messages are ignored, the message is lost, but TDP operation continues.

Generated By: TDP.

Notes: This condition is indicated by a system dump rather than a message. The abnormal termination reason code (in

R15) contains the error codes from the system dependent ISSUE-OPERATOR-MESSAGE service. For MVS, if the reason code contains X’00000810’, then the system WTO service failed with the return code preserved in General Register 3 at the time of the abnormal termination. Codes X’50’ through X’64’, inclusive, indicate various system console or hardcopy log problems.

Remedy: Collect diagnostic information (including the memory dump, if any) and contact Customer Support personnel.

More information

Teradata error 5 – 58 Messages

Teradata error 12113 One or more abnormality category events have been discarded.

Teradata error 9552 statistics cache hit ratio is lower than the threshold set in dbs control internal field.

Teradata error 6873 Only user DBC can create Internal Types.

Teradata error 19 File name too long

Teradata error 9 End-of-file

Teradata error 5035 An unexpected FSG error has occurred.

Teradata error TDP1308 ERP SENSE COMMAND FAILED FOR DEVICE devnum

Teradata error TDP1599 SENSE STATUS LOST

Teradata error 11414 System state value is undefined.